Image

CTI Ablation Guided by Omnipolar Wave Speed and Voltage Maps to Diminish RF and Fluoroscopy Times

CTI Ablation Guided by Omnipolar Wave Speed and Voltage Maps to Diminish RF and Fluoroscopy Times

Not Recruiting
18 years and older
All
Phase N/A

Powered by AI

Overview

Prospective randomized study involving patients with typical flutter (TF) undergoing cavo-tricuspid isthmus (CTI) radiofrequency ablation. The aim is to compare the results of 3 different new ablation strategies using Omnipolar technology to classic linear ablation.

The investigators´ aim is to compare the effectiveness, safety and procedure times of CTI ablation with 3 different strategies using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter to optimize radiofrequency (RF) and fluoroscopy times with classical linear ablation.

The number of patients needed to prove the investigators´ hypothesis is of at least 50 per group (total of 200 prospective patients

Description

Background Ablation procedures for CTI-dependent TF have classically been guided by fluoroscopy and intracavitary electrograms from diagnostic catheters placed in the right atrium (RA), the coronary sinus (CS) and the CTI (ablation catheter). Over the last few years, the use of navigators has increased considerably not only for complex procedures, but also for simple procedures, with the aim of reducing and even completely eliminating irradiation to both the patient and the operator (1). The investigators´ group is looking to characterize the high voltage and the low velocity regions in the CTI to minimize the procedure times. This has been addressed in a recent observational study with very good results.

Rationale There is increasing evidence of the benefits using 3D-systems not only to diminish fluoroscopy, but also to guide ablation targeting high voltage areas in the CTI (2-5). It is well known also the existence of low speed areas in the CTI, facilitating the presence of reentrant circuits (6,7). Currently, the investigators´ center performs all CTI ablation procedures using a 3D-navigator system, mostly with zero or minimal fluoroscopy. The investigators´ group has carried out a preliminary study with 13 patients to assess the effectiveness of CTI ablation with the use of the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter. In this observational study the investigators were able to characterize the high voltage and the low velocity regions in the CTI to minimize the RF lesions and procedure times. Acute bidirectional block was achieved in 100% of patients with an average fluoroscopy time of 1 ± 2 min (77% patients with zero fluoroscopy) and an average RF time of 5,7 ± 3,2 min (38% below 3 min). This results were significantly lower than results obtained with classical linear ablation: median fluoroscopy time 19.3 min, IQR 12.9 to 36.4 min, median fluoroscopy dose 3520.7 cGycm(2), IQR 1700.0 to 6709.0 cGycm(2).

From the investigators´ point of view this observational study, together with previous evidence justify a randomized study in order to confirm our hypothesis:

Hypothesis Omnipolar technology is able to guide the ablation procedure minimizing both the RF time and the fluoroscopy time (compared to linear ablation) by targeting only the critical regions on the CTI. Therefore Omnipolar technology will diminish RF time and fluoroscopy time/exposition compared to classical CTI ablation, and by means of this the investigators expect an inferior complications rate. Importantly acute success rate and 6 months follow-up recurrences rate will remain similar.

OBJECTIVES

  • Primary objectives: to optimize procedure times of CTI ablation with 3 different strategies based in voltage and/or conduction velocity maps using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter compared to classical linear ablation.
    • Specific objectives: Fluoroscopy time, radiofrequency time, radiation dose, percentage of zero-fluoroscopy procedures, acute efficacy, complications rate.
  • Secondary objectives: to increase the effectiveness of CTI ablation with 3 different strategies based in voltage and/or conduction velocity maps using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter compared to classical linear ablation.
  • Specific objectives: Recurrences rate at 6 months.

Eligibility

Inclusion Criteria:

  • Patients submitted to CTI ablation for TF
  • Age above 18 years

Exclusion Criteria:

• Life expectancy of <1 year

Study details
    Flutter

NCT05709795

Parc de Salut Mar

13 May 2026

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.