Overview

Prospective, non-randomized, , multicenter study with two independent arms:

  • Primary Study Arm - TAAA and Pararenal aneurysms requiring only TAMBE System. Hypothesis-driven analysis.
  • Up to 65 additional subjects may be implanted in Continued Access Phase under the Primary Study Arm only
  • Secondary Study Arm - TAAA requiring TAMBE System and CTAG Device(s). Non hypothesis-driven analysis.

Minimum: 122 implanted subjects. Maximum: 202 implanted subjects with up to 65 additional subjects implanted in Continued Access (Primary Study arm)

Eligibility

Inclusion Criteria:

  1. Aortic aneurysm involving the visceral vessels requiring treatment defined as at least one of the following:
    • Fusiform aneurysm diameter ≥ 5 cm
    • Saccular aneurysm (no diameter requirement)
    • Rapid aneurysm growth (≥ 5 mm in one year)
  2. Aortic aneurysm that involves the abdominal aorta, with:
    • Involvement of at least one visceral vessel and aneurysmal extension as far as 65 mm proximal to the celiac artery, and/or
    • No normal aorta between the upper extent of aneurysm and renal artery(s)
  3. Adequate access for TAMBE Device components (femoral, axillary, and / or brachial

    arteries as required)

  4. Age ≥ 19 years at the time of informed consent signature
  5. Male or infertile female
  6. Patient assessment favors an endovascular approach when compared to open surgical repair, as deemed by the treating physician
  7. Capable of complying with protocol requirements, including follow-up
  8. An Informed Consent Form signed by Subject or legal representative
  9. Sufficient distal landing zones in both iliac arteries, with at least one patent internal iliac artery and without planned placement of a branched iliac device, or planned coverage/occlusion/embolization of any patent internal iliac artery.
  10. Appropriate aortic anatomy to receive the TAMBE Device defined as all of the
    following
    • For the TAMBE aortic component, proximal aortic landing zone diameters between 22-34 mm
    • Proximal seal zone ≥ 20 mm in length
    • Aortic neck angle ≤ 60°
    • Distal landing zone (iliac arteries) 8-25 mm
    • Distal seal zone in iliac arteries of at least 10 mm in length
    • Renal artery landing zone diameters between 4-10 mm
    • Celiac and superior mesenteric artery landing zone diameters between 5-12 mm
    • ≥ 15 mm landing zone in each branch vessel
    • Landing zones in the proximal and distal aorta and all branch vessels cannot be aneurysmal, heavily calcified, or heavily thrombosed
    • Patent left subclavian artery

Secondary Study Arm Only:

         11. If aneurysm extends greater than 65 mm above celiac artery, proximal extension with a
             CTAG Device is required. The aortic landing zone diameter treatment range with the
             CTAG Device is 19.5-32 mm
         12. The most proximal aspect of the aneurysm is at least 2.0 cm distal to the left
             subclavian artery.
         13. The most proximal aortic device seal zone will be within native aorta or a
             previously-deployed TAG or CTAG Device • Placement inside a Dacron graft or another
             device manufacturer's stent graft will not be supported
        Exclusion Criteria:
        The patient is / has:
          1. Prior open, aortic surgery of the ascending aorta or aortic arch
          2. Ruptured or leaking aortic aneurysm
          3. Aneurysmal dilatation due to chronic aortic dissection
          4. Infected aorta
          5. Mycotic aneurysm
          6. Life expectancy <2 years
          7. Myocardial infarction or stroke within 1 year of treatment (staged or index procedure)
          8. Systemic infection which may increase risk of endovascular graft infection
          9. Degenerative connective tissue disease, e.g. Marfan's or Ehler-Danlos Syndrome
         10. Participation in an investigational drug study (within 30 days of last administration)
             or investigational medical device study (within 1 year of implant) from the time of
             study screening
         11. History of drug abuse, e.g. cocaine or amphetamine or alcohol, within 1 year of
             treatment
         12. Tortuous or stenotic iliac and / or femoral arteries and the inability to use a
             conduit for vascular access
         13. A branch vessel(s) that is dissected or has significant calcification, tortuosity,
             thrombus formation that would interfere with device delivery or ability to exclude
             from blood flow
         14. Known sensitivities or allergies to the device materials
         15. Previous instance of Heparin Induced Thrombocytopenia type 2 (HIT-2) or known
             hypersensitivity to heparin
         16. Patient has body habitus or other medical condition which prevents adequate
             fluoroscopic and CT visualization of the aorta
         17. Renal Insufficiency (creatinine value > 1.8 mg/dL, GFR < 30, or patient undergoing
             dialysis)
         18. Known concomitant aneurysm of the ascending aorta or aortic arch anticipated to
             require surgical intervention within one year of study treatment

Study details
    Thoracoabdominal Aortic Aneurysm

NCT03728985

W.L.Gore & Associates

21 November 2025

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.