Image

Lattice-tip Versus Irrigated-tip Catheter for Linear Ablation of the Cavotricuspid Isthmus. A Multicenter, Randomized Study.

Lattice-tip Versus Irrigated-tip Catheter for Linear Ablation of the Cavotricuspid Isthmus. A Multicenter, Randomized Study.

Recruiting
18 years and older
All
Phase N/A

Powered by AI

Overview

The LINEAR study is designed to compare the procedural efficacy, efficiency and safety of linear radiofrequency ablation of the cavotricuspid istmus using either a standar irrigated-tip ablation catheter or lattice-tip ablation catheter .The primary focus of the acute procedural data analysis will be:

Procedural efficacy: This will be evaluated based on the rate of bidirectional CTI block persistence after 60 min waiting period documented by high resolution activation mapping. Furthermore, provocative test with intravenous adenosine infusion will be conducted to exclude dormant CTI conduction.

Procedural efficiency: This will be evaluated based on the number of RF lesions delivered, time to achieve bidirectional CTI block, and fluoroscopy exposure time.

Procedural safety: The incidence of procedural complications will be recorded.

Description

This is a prospective, multicenter, randomized controlled trial designed to compare the efficacy, efficiency and safety of CTI catheter ablation using two different catheter technologies: the lattice-tip, dual-energy catheter (Sphere-9, Medtronic) and the irrigated radiofrequency (RF) catheter (ThermoCool® SmartTouch™, Biosense Webster, USA). The primary focus of the acute procedural data analysis will be:

Procedural efficacy: This will be evaluated based on the rate of bidirectional CTI block persistence after 60 min waiting period documented by high resolution activation mapping. Furthermore, provocative test with intravenous adenosine infusion will be conducted to exclude dormant CTI conduction.

Procedural efficiency: This will be evaluated based on the number of RF lesions delivered, time to achieve bidirectional CTI block, and fluoroscopy exposure time.

Procedural safety: The incidence of procedural complications will be recorded.

Patient Population Based on previously published data, the proportion of patients with documented CTI bidirectional block at 60 minutes as assessed by high density electroanatomical mapping is estimated at 60% for the control group. Based on preliminary studies conducted by our group, we expected a respective percentage of bidirectional block of 85% in the intervention group. Hence, for a superiority design with two-sided α of 0.05, equal (1:1) allocation between groups and 80% power, 48 patients per group (96 in total) were estimated as the target sample size. As the outcome is assessed intraprocedurally, no dropouts are expected, and therefore no further adjustments were made to the sample size estimations.

Patients will be prospectively randomized in a 1:1 ratio to one of two treatment groups:

  • Group A: Patients undergoing CTI catheter ablation using RF energy delivered by the lattice-tip, dual-energy catheter (Sphere-9, Medtronic).
  • Group B: Patients undergoing CTI catheter ablation using RF energy delivered by the irrigated RF catheter (ThermoCool® SmartTouch™, Biosense Webster, USA).

Ablation Procedure All participants will receive anticoagulation therapy for a minimum of one month prior to the ablation procedure. All anti-arrhythmic drugs (AADs) will be discontinued at least five half-lives before the procedure. General anesthesia (GA) will be utilized in both groups.

A decapolar electrode catheter will be positioned in the coronary sinus (CS) before the commencement of ablation. In patients presenting with sinus rhythm, ablation will be performed during pacing from the proximal CS bipole at a cycle length of approximately 600 ms. For patients presenting with typical atrial flutter, pacing will be initiated following termination of the flutter.

CTI ablation will be performed using a point-by-point catheter technique, creating a contiguous line of lesions along the CTI, guided by fluoroscopy, electroanatomical mapping. The catheter will be gently dragged from the tricuspid valve annulus towards the inferior vena cava. Intracardiac echocardiography (ICE) will be utilized as an adjunct in cases where bidirectional block is not readily achieved, to further evaluate potential anatomical variations.

In Group A, only RF energy will be delivered using the dual-energy focal 9 mm lattice-tip catheter (Sphere-9; Medtronic) according to the recommended settings. Pulsed field ablation will not be employed in this group.

In Group B, the VISITAG module will be utilized to tag the location of each RF lesion application, with the following settings: stability range of 2-3 mm, stability duration of 3-5 s, force over time of 25%, and a tag size diameter of 3 mm. The power setting will be at 30 W with a target contact force of 10-30 g and a target Ablation Index value of 400. Saline irrigation will be administered at a rate of 30 mL/min, and the temperature limit will be set at 43 °C.

Primary Efficacy Endpoint The primary procedural endpoint for efficacy will be the achievement of bidirectional CTI block. After completion of the CTI line, bidirectional block will be confirmed through differential pacing maneuvers followed by activation mapping, performed using the Affera mapping system for Group A and the CARTO mapping system for Group B, respectively. Activation mapping will be repeated 60 minutes after the initial documentation of bidirectional block to assess for its persistence or the presence of spontaneous recovery of CTI conduction

Primary Safety Endpoint The incidence of procedural complications will be recorded.

Eligibility

Inclusion Criteria:

  • patients above 18 years of age undergoing CTI ablation

Exclusion Criteria:

  • Prior right atrium ablation

Study details
    Catheter Ablation

NCT07078760

Mitera Hospital

15 October 2025

Step 1 Get in touch with the nearest study center
We have submitted the contact information you provided to the research team at {{SITE_NAME}}. A copy of the message has been sent to your email for your records.
Would you like to be notified about other trials? Sign up for Patient Notification Services.
Sign up

Send a message

Enter your contact details to connect with study team

Investigator Avatar

Primary Contact

  Other languages supported:

First name*
Last name*
Email*
Phone number*
Other language

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.