Image

Rotator Cuff Tendon Repair With FiberLocker System Patch Augmentation

Rotator Cuff Tendon Repair With FiberLocker System Patch Augmentation

Recruiting
40-65 years
All
Phase N/A

Powered by AI

Overview

The overall objective of this clinical investigation is to assess the safety and efficacy of full-thickness arthroscopic rotator cuff repairs augmented with the FiberLocker System for the subjects. The primary outcome of the investigation is to assess the safety after full-thickness arthroscopic rotator cuff repairs augmented with the FiberLocker System in terms of postoperative adverse events through the 12-month follow-up. Main secondary outcomes include measures of efficacy and clinical performance evaluated at 6-week, 4.5-month, and 12-month follow-ups including retear rate assessed using MRI and different functional performance scores.

Eligibility

Inclusion Criteria:

  1. Subject requires surgical treatment of a full-thickness rotator cuff tear, according to Balgrist standard procedure
  2. Full-thickness tear of the supraspinatus or combined infraspinatus and supraspinatus
  3. The rotator cuff tear is of traumatic origin.
  4. Subject is ≥ 40 years of age & ≤ 65 years of age.
  5. Primary rotator cuff repair
  6. Informed Consent signed by the subject
  7. Pre-operative MRI performed

Exclusion Criteria:

  1. Vulnerable subjects (as defined in ISO 14155)
  2. Subjects who do not have the power of judgement or are unable to fully understand all aspects of the investigation that are relevant to the decision to participate
  3. Participation in another investigation with an investigational drug or another MD within the 30 days preceding and during the present investigation,
  4. Previous enrolment into the current investigation,
  5. Enrolment of the PI, his/her family members, employees and other dependent persons,
  6. Inability to follow the procedures of the investigation, or known or suspected non-compliance, e.g. due to language problems, psychological disorders, dementia, drug or alcohol abuse, etc. of the subject
  7. Active smoker
  8. History of claustrophobia that would prevent an MRI of the index shoulder
  9. Presence of an implanted metallic device or other implants that would contraindicate acquisition or inhibit radiologist review of an MRI of the index shoulder
  10. Pregnant or planning to become pregnant during the study period
  11. Breast feeding women
  12. Subject has conditions or circumstances that would interfere with study requirements.
  13. Contraindications and limitations of the MD as described in the IFUs.
  14. Partial rotator cuff tears
  15. History or known allergy or intolerance to polyester
  16. Complete full-thickness subscapularis tears greater than the superior 1/3 of the tendon, with Lafosse grade 3 or greater
  17. Massive rotator cuff tears, tear size equal to or greater than 4 cm in the anterior-posterior dimension or irreparable rotator cuff tear
  18. Limited space or exposure for implant delivery
  19. Structural or pathological condition of the bone or soft tissue that could impair healing.
  20. Intraoperative rotator cuff tear characteristics differ from preoperatively expected characteristics and fulfil one of the abovementioned criteria
  21. Fatty infiltration of the index shoulder rotator cuff muscle > Goutallier Score 2
  22. Corticosteroid injection in the operative shoulder within 6 weeks of operation
  23. Subject shows frozen shoulder/adhesive capsulitis at day of surgery
  24. Cases of moderate to severe osteoarthritis
  25. Patients with inflammatory disease or auto-immune based joint diseases (e.g., rheumatoid arthritis, systemic lupus erythematosus, arthropathy)
  26. Subjects with diabetes type I or II
  27. The subject currently has an acute infection in the area surrounding the surgical site
  28. Evidence of active infection, osteomyelitis, sepsis or distant infection which could spread to the index joint.
  29. Any comorbidity or condition that renders the patient a poor surgical candidate as determined by the Investigator.

Study details
    Rotator Cuff Tear
    Rotator Cuff Injury
    Rotator Cuff Rupture

NCT07005063

ZuriMED Technologies AG

15 October 2025

Step 1 Get in touch with the nearest study center
We have submitted the contact information you provided to the research team at {{SITE_NAME}}. A copy of the message has been sent to your email for your records.
Would you like to be notified about other trials? Sign up for Patient Notification Services.
Sign up

Send a message

Enter your contact details to connect with study team

Investigator Avatar

Primary Contact

  Other languages supported:

First name*
Last name*
Email*
Phone number*
Other language

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.