Image

Rhythm Express Wearable System vs. Simultaneous Polysomnography for the Diagnosis of Obstructive Sleep Apnea in Adults With Suspected or Observed Atrial Fibrillation

Rhythm Express Wearable System vs. Simultaneous Polysomnography for the Diagnosis of Obstructive Sleep Apnea in Adults With Suspected or Observed Atrial Fibrillation

Non Recruiting
21-85 years
All
Phase N/A

Powered by AI

Overview

The goal of this observational study is to confirm the accuracy of the sleep algorithm (software) used in the Rhythm Express Wearable System to detect sleep apnea severity. The study involves participants wearing the RX-1 mini cardiac monitor on their chest and a pulse oximeter during a traditional sleep test, known as polysomnography (PSG), conducted in a sleep center. The performance of the device will be evaluated by comparing the results from the Rhythm Express Wearable System with those from the traditional Polysomnography(PSG).

Participants will:

  1. Complete a Screening Visit to confirm they are eligible to participate in the study.
  2. Be trained on the use of the Rhythm Express Wearable System.
  3. Wear the RX-1 mini cardiac monitor on their chest for 3-5 days/nights.
  4. Wear a pulse oximeter for 2 nights before a scheduled sleep study.
  5. Complete a sleep study while wearing the Rhythm Express Wearable System.
  6. Complete a telephone follow-up visit 5-10 days after the sleep study.

Description

AF is a chronic, progressive, and debilitating cardiovascular disease that exacerbates other cardiovascular diseases and is a leading cause of morbidity (associated illness) and mortality (death). In addition, AF is the most common cardiac arrhythmia that leads to more hospitalizations than any other arrhythmia. Sleep disorders are also associated with a threefold increased mortality and literature suggests a doubled risk for stroke in people with OSA. Identification of OSA and treatment with CPAP is associated with a reduction in the stroke risk for OSA. Thus, early identification and treatment of AF and OSA may be of major societal benefit in reducing mortality and morbidity.

The Rhythm Express Wearable System consists of the RX-1 mini Cardiac Monitor, a Nonin or Viatom Pulse Oximeter, and an Android Cell Phone with the Rhythm Express Oximetry Application. The RS-1 Sleep Algorithm is a cloud-based software as a medical device (SWMD) that receives inputs from the two FDA-cleared wearable devices. The Algorithm, together with the two wearable devices, comprises the Rhythm Express Wearable System.

This multi-center, prospective, observational, confirmatory study is designed to compare sleep apnea severity classification provided by the RS-1 Sleep Algorithm with Polysomnography (PSG). The proposed research will confirm the accuracy of using the Rhythm Express Wearable System to detect apnea/hypopnea index of at least 5/15/30 in patients with observed or suspected atrial fibrillation by comparing it to data recorded in a PSG, which is considered to be the gold standard for sleep testing. In addition, the ability of the RX-1 mini to detect sleep and assess posture and respiratory rate during sleep will be evaluated.

This initiative represents a significant step towards simplifying the screening process for sleep disorders in people indicated for ambulatory cardiac monitoring.

Eligibility

Inclusion Criteria:

  1. Male or female between 21-85 years of age at the time of informed consent.
  2. Subject has a documented or suspected atrial fibrillation.
  3. Subject has an indication for 48+ hours of cardiac monitoring due to non-sustained/paroxysmal atrial arrhythmias.
  4. STOP-BANG ≥ 2.
  5. Subject has capable cellular service at home.
  6. Willingness and ability to comply with the study protocol, including informed consent, all study visits, and the collection of adverse events at the telephone follow-up visit.
  7. Life expectancy > 6 months.
  8. Well-defined and stable diurnal behaviors and nocturnal sleep pattern defined as:
    1. Subject sets aside ample time to sleep to avoid insufficient sleep.
    2. Subject does not do shift work (work outside of the traditional 9 to 5 shift).

Exclusion Criteria:

  1. Uses short acting nitrates within 3 hours of the sleep study.
  2. Has a permanent pacemaker or ICD.
  3. Sustained atrial fibrillation or sustained supraventricular arrhythmias.
  4. Known congestive heart failure Class ≥ 1 or known LVEF < 45%.
  5. Active acute pulmonary exacerbation (e.g., pneumonia or bronchitis).
  6. Known serious respiratory or central nervous system disease that may alter respiratory pattern.
  7. Currently participating in or plans to participate in another study that could confound the results of this study.
  8. Cognitive or mental health status that would interfere with study participation and/or proper informed consent.
  9. Presence of other active medical conditions which could significantly alter pulmonary function.
  10. Recent (within 28 days) or expected (during study participation) travel over four or more time zones.
  11. History of opioid usage within the past 30 days.
  12. Diagnosis of insomnia that is not controlled by medication or other means.
  13. Currently using CPAP machine.

Study details
    Obstructive Sleep Apnea (OSA)
    Atrial Fibrillation (Paroxysmal)
    Palpitations

NCT06907888

VivaQuant

20 August 2025

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.