Image

Quantitative Susceptibility Mapping (QSM) to Guide Iron Chelating Therapy

Quantitative Susceptibility Mapping (QSM) to Guide Iron Chelating Therapy

Recruiting
2 years and older
All
Phase N/A

Powered by AI

Overview

The overall goal of this research is to help develop a new magnetic resonance (MR) method, Quantitative Susceptibility Mapping (QSM), to improve the measurement of liver iron concentrations without the need for a liver biopsy. Measurement of liver iron is important to diagnose and treat patients who have too much iron in their bodies (iron overload). Liver iron measurements by current MRI methods (R2 and R2) can be inaccurate because of the effects of fat, fibrosis and other abnormalities. QSM should not be affected by these factors and should be free of these errors. In this study, MRI measurements (QSM, R2 and R2) of iron in patients before liver transplant will be compared with chemical analysis of iron in liver explants (livers removed from patients undergoing liver transplant). The liver explants would otherwise be discarded. Investigators expect that this study will show that the new MRI method, QSM, is superior to the current MRI methods, R2 and R2*.

Description

The overall objective of this research is to improve the safety of iron-chelating therapy (ICT) in patients with transfusional iron overload by developing an accurate non-invasive measurement of the liver iron concentration (LIC), the best measure of the body iron burden in all forms of systemic iron overload. The scientific premise is that quantitative susceptibility mapping (QSM) provides a quantitative biophysical connection to LIC. Safe ICT requires careful adjustment of the iron chelator dose to the body iron burden to optimize iron excretion while avoiding chelator toxicity, including gastrointestinal disorders, audiovisual impairment, neutropenia, arthropathy, growth retardation, and hepatic and renal failure. QSM enables accurate measurement of LIC by overcoming the inherent cellular interference in current R2 (=1/T2) and R2 (=R2+R2') estimates that lack a well-defined biophysical connection to the LIC. A fundamental biophysical limitation of the R2 and R2 approaches is that intravoxel contents other than iron, including fibrosis, steatosis and necroinflammation, also alter relaxation. In the liver, paramagnetic iron stored in ferritin and hemosiderin is the dominant susceptibility source for QSM. Consequently, magnetic susceptibility measured by QSM has a simple linear relationship with the concentration of iron in the liver and is little affected by fibrosis, steatosis and necroinflammation. The investigator's research plan has 3 specific aims:

Aim 1. Develop hQSM for accurate measurement of LIC without interfering errors. Investigators will optimize data acquisition and processing for free-breathing navigator acquisition with robust fat-water separation.

Aim 2. Validate hQSM using histology and chemical measurement of LIC in liver explants. Investigators will assess the accuracies of LICs measured by hQSM and R2* in patients before liver transplant with histologic examination using the reference standard of chemical measurement of LIC in liver explants.

Aim 3. Evaluate hQSM in patients with transfusional iron overload under ICT. In patients regularly transfused for thalassemia major, investigators will conduct a double-blind clinical study comparing the accuracy of hQSM and R2* in measuring annual changes in LIC, using regression against the year-long amount of iron administered in red blood cell transfusions and the year-long cumulative dose of iron chelator.

Eligibility

Inclusion Criteria:

  • Established diagnosis of thalassemia major
  • Treatment with deferasirox formulated as JadenuĀ® as the sole iron chelating therapy (ICT)
  • Regular transfusion with records maintained in the Cornell Thalassemia Program
  • 2 years of age or older
  • Females who are not pregnant

Inclusion Criteria (for healthy subjects):

  • Men and women aged 21 years or older
  • Able and willing to give consent
  • No known hematological and liver disease
  • No contraindications for MRI

Exclusion Criteria:

  • A history of auditory or ocular toxicity related to ICT
  • A history of poor adherence to prescribed therapy
  • An inability to tolerate MRI examinations
  • Treatment for mental illness
  • Institutionalization or imprisonment

Study details
    MRI Scans

NCT04171635

Weill Medical College of Cornell University

27 January 2024

Step 1 Get in touch with the nearest study center
We have submitted the contact information you provided to the research team at {{SITE_NAME}}. A copy of the message has been sent to your email for your records.
Would you like to be notified about other trials? Sign up for Patient Notification Services.
Sign up

Send a message

Enter your contact details to connect with study team

Investigator Avatar

Primary Contact

  Other languages supported:

First name*
Last name*
Email*
Phone number*
Other language

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.