Image

An Early Feasibility Study of the HighLife 28mm Trans-Septal Transcatheter Mitral Valve Replacement System

An Early Feasibility Study of the HighLife 28mm Trans-Septal Transcatheter Mitral Valve Replacement System

Recruiting
18 years and older
All
Phase N/A

Powered by AI

Overview

Study to evaluate the feasibility, safety and performance of the HighLife trans-septal Transcatheter Mitral Valve in patients with moderate-severe and severe mitral regurgitation who are at high risk for surgical treatment.

Description

Protocol Title:

An Early Feasibility Study of the HighLife 28mm Transcatheter Trans-Septal Mitral Valve Replacement System

Protocol # HL-2019-01, ver. 5.0

Phase: United States Early Feasibility Study

Investigational Devices:

The HighLife 28mm Trans-Septal Mitral Valve and its delivery systems. These devices compose the HighLife Trans-septal Mitral Valve Replacement (TSMVR) System.

  • Size 28 mm TMV (CLARITY valve)
  • Size 28 mm TMV-L (CLARITY large annulus valve/ LAV)

Intended Use: The HighLife TSMVR system is intended for the trans-septal access percutaneous mitral valve replacement in patients suffering from symptomatic moderate-severe or severe mitral regurgitation (MR) due to primary (degenerative) or secondary (functional) abnormality of the mitral valve.

Device Description:

The HighLife TSMVR system is composed of a Trans-Septal (Mitral Valve (TSMV), a sub-annular implant (SAI), and their delivery systems and accessories. The TMV is a 28 mm mitral bioprosthesis made of a self-expanding Nitinol frame covered with polyester graft and supporting bovine pericardium leaflets. The bioprosthesis is used in conjunction with the Sub-Annular Implant (SAI), comprising a ring (made of polycarbonate urethane (PCU), nitinol, gold markers and polyester (Dacron) to be placed around the mitral valve apparatus to stabilize the position of the mitral valve implant.

Design: A single arm, prospective, multicenter, non-randomized and open-labelled study.

Purpose: The purpose of the study is to evaluate the feasibility, safety and performance of the HighLife 28mm Trans-septal Mitral Valve Replacement (TSMVR) system in NYHA Class ≥ II-IV patients with moderate-severe or severe mitral regurgitation who are at high risk for surgical treatment or deemed more appropriate to receive transcatheter mitral valve replacement than to receive conventional mitral valve surgery according to the local multidisciplinary Heart Team.

Objectives: Primary objectives are to evaluate the feasibility, safety and performance of the HighLife 28mm TSMVR system at 30 days. Secondary objectives are to evaluate long term safety and performance of the HighLife TSMVR system.

Eligibility

Inclusion Criteria:

  • Age ≥ 18 years
  • Severe mitral regurgitation
  • New York Heart Association (NYHA) Functional Class II, III or ambulatory IV.
  • Patient is under maximally tolerated GDMT (incl. CRT) for at least 3 months
  • Multidisciplinary Heart Team consensus that the patient is inoperable or at high-risk for surgical repair/replacement due to significant co-morbid conditions
  • Multidisciplinary Heart Team consensus that the patient is not a suitable candidate for other approved percutaneous repair therapy due to anatomical or medical conditions
  • Patient meets the anatomical criteria for HighLife valve sizing as determined by CT and TEE

Main Exclusion Criteria:

  • Mitral stenosis
  • Rheumatic valve disease
  • Severe calcifications of the mitral annulus and/or mitral leaflets
  • Prior surgical or interventional treatment of the mitral valve
  • Unsuitable anatomy for the transapical access
  • Unsuitable anatomy of the aorta and ilio-femoral vessels for the transfemoral access
  • Untreated clinically significant coronary artery disease requiring revascularization
  • LVEF < 30%
  • LVEDD > 70mm
  • Echocardiographic evidence of intracardiac mass, thrombus or vegetation
  • Hypertrophic Obstructive Cardiomyopathy (HOCM)
  • Any surgical or interventional procedure (including PCI) done in the past 30 days prior to procedure

Study details
    Mitral Regurgitation

NCT04029337

HighLife SAS

16 February 2024

Step 1 Get in touch with the nearest study center
We have submitted the contact information you provided to the research team at {{SITE_NAME}}. A copy of the message has been sent to your email for your records.
Would you like to be notified about other trials? Sign up for Patient Notification Services.
Sign up

Send a message

Enter your contact details to connect with study team

Investigator Avatar

Primary Contact

  Other languages supported:

First name*
Last name*
Email*
Phone number*
Other language

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.