Overview
Background: Recommendations for peri-operative management in patients with implanted cardiac electronic devices (CIED) are often based on older data from case reports and small collectives.
Objective: To evaluate the peri-operative management and outcome of patients with implanted CIED undergoing non-CIED related surgery or catheter-interventional procedures in clinical routine.
Study design: bi-center, non-randomized, observational registry, retrospective data-collection, on-going prospective patient enrollment, descriptive statistics
Primary endpoint: number and type of peri-operative adverse device related events (ADE) Secondary endpoints: pre-interventional data (patient characteristics, data from CIED interrogation); peri-interventional data (type of surgery/intervention, anesthesiology techniques, any AE), postinterventional data (data from post-interventional CIED interrogation, need for reprogramming / device revision).
Inclusion criteria: implanted CIED, non-CIED related surgical or catheter-based intervention, peri-procedural CIED interrogation, age >18 years Exclusion criteria: no implanted CIED, no data from any peri-procedural CIED interrogation available
Patient enrollment: retrospectively beginning from 2008, further on-going prospective inclusion Sample size: For the observational study, there is no pre-specified sample size. Data from more than 500 patients undergoing > 700 interventions are expected.
Description
Background: The number of worldwide implanted cardiac electronic devices (CIED) is increasing continuously. On the other hand, the number of (more and more complex) surgical and catheter based interventions in this population is increasing as well. Recommendations for peri-operative management are often based on older data from case reports and small collectives. Data especially in particular subpopulations is limited.
Objective: The study aims to evaluate the peri-operative management and outcome of patients with implanted CIED undergoing non-CIED related surgery or catheter interventional procedures (ablation) in clinical routine. Data from the study are expected to provide evidence for recommendations improving perioperative management and device programming.
Study design: bi-center, non-randomized, observational registry, retrospective data-collection, on-going prospective patient enrollment, descriptive statistics Centers: Klinikum Fuerth (dep. for Heart and Lung disease, section for clinical electrophysiology), Klinikum Nuernberg (dep. for Heart surgery).
Patients and methods:
Primary endpoint: number and type of peri-operative adverse device related events (ADE)
- all complaints, adverse events and adverse device effects will be documented and classified according to the ISO/DIS 14155 - Clinical Investigation of medical Devices in Human Subjects
- Good Clinical Practices with respect to their relationship to the surgical or catheter intervention and [Stark NJ. A New standard for medical device adverse event classification. J of Clinical Research Best Practices 2009; 5(12): 1-7].
Secondary endpoints: pre-interventional data (patient characteristics, data from CIED interrogation); peri-interventional data (type of surgery/intervention, anesthesiology techniques, any AE), post-interventional data (data from post-interventional CIED interrogation, need for reprogramming / device revision).
Subpopulations: cardiac surgery, vascular surgery, catheter ablation, ICD and mode of therapy inhibition, CRT, automatic features
Inclusion criteria:
patients with implanted CIED undergoing non-CIED related surgical or catheter-based procedure, peri-procedural CIED interrogation, age >18 years Exclusion criteria: no implanted CIED, no data from peri-procedural CIED interrogation available.
Patient enrollment: retrospectively from the clinical records beginning from 2008, further on-going prospective inclusion Data acquisition: Data will be collected in CRF´s from the patient's history, the computer based clinical information system / clinical records and data records from CIED interrogations
Sample size: For the observational study, there is no pre-specified sample size.
Data from more than 500 patients undergoing > 700 interventions are expected.
Data security: Study related data are collected by the study investigators in an anonymous clinic-internal data-base, that is password protected.
All investigators have to provide valid GCP training.
Risk estimation: the study is observational and descriptive with anonymized data collection/analysis and therefore adds no risk to the study population
Eligibility
Inclusion Criteria:
- implanted CIED (e.g. pacemaker, ICD, CRT),
- performed (non-CIED related) surgical or catheter-based procedure,
- data from peri-procedural CIED interrogation available
- age >18 years
Exclusion Criteria:
- no implanted CIED,
- no data from any peri-interventional CIED interrogation available