Overview

The primary purpose of this study is to evaluate the clinical performance of the Attune S+ knee primarily based on evaluation with use of Oxford Knee Score. The NexGen TKR will be used as reference standard. The second aim is to study component migration with model-based RSA in a subgroup of patients with model-based RSA and to compare these measurements with migration measurements with use of CT-based migration measurements. The investigators hypothesis is that the results two years after insertion of these two TKR designs will be about equal.

Description

The Attune knee was launched in 2012. From a clinical point of view some studies indicate superior clinical performance of the Attune when compared to the PFC. Carey and Harty operated 21 patients with both the Attune and the POFC Sigma knees. At six months' clinical scores were superior for the Attune side as was range of movement. Ranawat 2017, matched 100 Attune to 100 PFC Sigma knee operations based on age, gender, side and BMI but found no difference in clinical results after 2 years.

Bonutti reviewed three hospital databases and described 2 cases with loosening of the tibial component due to debonding between the cement and the implant, but the total material from which these cases were collected was not known or mentioned. Turgeon studied the fixation of 30 consecutive cases operated with the Attune knee and observed a mean maximum total point motion of 0.08 mm between 12 and 24 months, which suggests an acceptably low risk of medium to long-term failure due to aseptic loosening. Staats evaluated incidence of radiolucent lines in 276 Attune and 253 PFC Sigma TKRs up to one year after operation and observed a higher incidence in the former group.

In the last report from NJR from 2020, the 5-year revision rate of the Attune FB knee is 2.71 (2.32-3.17), which is slightly above average (2.23, 2.20-2.26). In the Australian registry from 2020 the corresponding cumulative percent revision rate of cemented Attune CR is 3.0 % (2.7 - 3.5) at 5 years.

In an ongoing study the investigators have randomized 95 knees with knee osteoarthritis to either become operated with an Attune knee (n=49) or a PFC knee (n=46). Preliminary results at one year show almost equal results when evaluated in terms of Oxford Knee or Forgotten Joint Scores.

NexGen metal-backed tibia is the most commonly used total knee prosthesis in Sweden. Its revision rate is one of the lowest observed in the Swedish Register. The 5 years survival in the report from NJR from 2020 is 2.1% (2.05 - 2.21) and in the report from the Australian register it is about equal (2.0; 1.9 - 2.2). The Australian Register also present survival at 19 years amounting to 5.7% (4.7 - 6.9) being the lowest cumulative revision of those specific cemented TKRs accounted for with that long follow up.

In 2017 DePuy launched the Attune S+ tibial components in order to address the potential problem of loosening between the cement and the tibial tray. If and if so, to what extent this modification will change the clinical outcome of TKRs operated with this implant is not known. Based on the high survival rate of the in Sweden frequently used NexGen TKR a comparative study between the Attune S+ and the NexGen TKRs would provide an important benchmark for the performance of the Attune S+ knee.

Eligibility

Inclusion Criteria:

  • Medial or lateral primary OA Ahlbäck Grade 2-4
  • Varus or valgus deformity ≤10 degrees, extension defect ≤10 degrees
  • Age 40-75 years
  • BMI <35
  • ASA 1-3.
  • Coming from independent living in own home
  • Written informed consent.

Exclusion Criteria:

  • Cortisone treatment during the last 6 months before operation
  • Neurological diseases with symptoms, stroke with sequel
  • Endocrine diseases with symptoms
  • OA secondary to trauma, infection, inflammatory disease or congenital and acquired deformities
  • BMI >=35

Study details

Arthroplasty, Replacement, Knee

NCT05464641

Göteborg University

26 January 2024

Step 1 Get in touch with the nearest study center
What happens next?
  • You can expect the study team to contact you via email or phone in the next few days.
  • Sign up as volunteer  to help accelerate the development of new treatments and to get notified about similar trials.

You are contacting

Investigator Avatar

Primary Contact

site

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.